123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208 |
- /*
- * Copyright (C) ST-Ericsson 2010 - 2013
- * Author: Martin Persson <martin.persson@stericsson.com>
- * Hongbo Zhang <hongbo.zhang@linaro.org>
- * License Terms: GNU General Public License v2
- *
- * When the AB8500 thermal warning temperature is reached (threshold cannot
- * be changed by SW), an interrupt is set, and if no further action is taken
- * within a certain time frame, kernel_power_off will be called.
- *
- * When AB8500 thermal shutdown temperature is reached a hardware shutdown of
- * the AB8500 will occur.
- */
- #include <linux/err.h>
- #include <linux/hwmon.h>
- #include <linux/hwmon-sysfs.h>
- #include <linux/mfd/abx500.h>
- #include <linux/mfd/abx500/ab8500-bm.h>
- #include <linux/mfd/abx500/ab8500-gpadc.h>
- #include <linux/module.h>
- #include <linux/platform_device.h>
- #include <linux/power/ab8500.h>
- #include <linux/reboot.h>
- #include <linux/slab.h>
- #include <linux/sysfs.h>
- #include "abx500.h"
- #define DEFAULT_POWER_OFF_DELAY (HZ * 10)
- #define THERMAL_VCC 1800
- #define PULL_UP_RESISTOR 47000
- /* Number of monitored sensors should not greater than NUM_SENSORS */
- #define NUM_MONITORED_SENSORS 4
- struct ab8500_gpadc_cfg {
- const struct abx500_res_to_temp *temp_tbl;
- int tbl_sz;
- int vcc;
- int r_up;
- };
- struct ab8500_temp {
- struct ab8500_gpadc *gpadc;
- struct ab8500_btemp *btemp;
- struct delayed_work power_off_work;
- struct ab8500_gpadc_cfg cfg;
- struct abx500_temp *abx500_data;
- };
- /*
- * The hardware connection is like this:
- * VCC----[ R_up ]-----[ NTC ]----GND
- * where R_up is pull-up resistance, and GPADC measures voltage on NTC.
- * and res_to_temp table is strictly sorted by falling resistance values.
- */
- static int ab8500_voltage_to_temp(struct ab8500_gpadc_cfg *cfg,
- int v_ntc, int *temp)
- {
- int r_ntc, i = 0, tbl_sz = cfg->tbl_sz;
- const struct abx500_res_to_temp *tbl = cfg->temp_tbl;
- if (cfg->vcc < 0 || v_ntc >= cfg->vcc)
- return -EINVAL;
- r_ntc = v_ntc * cfg->r_up / (cfg->vcc - v_ntc);
- if (r_ntc > tbl[0].resist || r_ntc < tbl[tbl_sz - 1].resist)
- return -EINVAL;
- while (!(r_ntc <= tbl[i].resist && r_ntc > tbl[i + 1].resist) &&
- i < tbl_sz - 2)
- i++;
- /* return milli-Celsius */
- *temp = tbl[i].temp * 1000 + ((tbl[i + 1].temp - tbl[i].temp) * 1000 *
- (r_ntc - tbl[i].resist)) / (tbl[i + 1].resist - tbl[i].resist);
- return 0;
- }
- static int ab8500_read_sensor(struct abx500_temp *data, u8 sensor, int *temp)
- {
- int voltage, ret;
- struct ab8500_temp *ab8500_data = data->plat_data;
- if (sensor == BAT_CTRL) {
- *temp = ab8500_btemp_get_batctrl_temp(ab8500_data->btemp);
- } else if (sensor == BTEMP_BALL) {
- *temp = ab8500_btemp_get_temp(ab8500_data->btemp);
- } else {
- voltage = ab8500_gpadc_convert(ab8500_data->gpadc, sensor);
- if (voltage < 0)
- return voltage;
- ret = ab8500_voltage_to_temp(&ab8500_data->cfg, voltage, temp);
- if (ret < 0)
- return ret;
- }
- return 0;
- }
- static void ab8500_thermal_power_off(struct work_struct *work)
- {
- struct ab8500_temp *ab8500_data = container_of(work,
- struct ab8500_temp, power_off_work.work);
- struct abx500_temp *abx500_data = ab8500_data->abx500_data;
- dev_warn(&abx500_data->pdev->dev, "Power off due to critical temp\n");
- kernel_power_off();
- }
- static ssize_t ab8500_show_name(struct device *dev,
- struct device_attribute *devattr, char *buf)
- {
- return sprintf(buf, "ab8500\n");
- }
- static ssize_t ab8500_show_label(struct device *dev,
- struct device_attribute *devattr, char *buf)
- {
- char *label;
- struct sensor_device_attribute *attr = to_sensor_dev_attr(devattr);
- int index = attr->index;
- switch (index) {
- case 1:
- label = "ext_adc1";
- break;
- case 2:
- label = "ext_adc2";
- break;
- case 3:
- label = "bat_temp";
- break;
- case 4:
- label = "bat_ctrl";
- break;
- default:
- return -EINVAL;
- }
- return sprintf(buf, "%s\n", label);
- }
- static int ab8500_temp_irq_handler(int irq, struct abx500_temp *data)
- {
- struct ab8500_temp *ab8500_data = data->plat_data;
- dev_warn(&data->pdev->dev, "Power off in %d s\n",
- DEFAULT_POWER_OFF_DELAY / HZ);
- schedule_delayed_work(&ab8500_data->power_off_work,
- DEFAULT_POWER_OFF_DELAY);
- return 0;
- }
- int abx500_hwmon_init(struct abx500_temp *data)
- {
- struct ab8500_temp *ab8500_data;
- ab8500_data = devm_kzalloc(&data->pdev->dev, sizeof(*ab8500_data),
- GFP_KERNEL);
- if (!ab8500_data)
- return -ENOMEM;
- ab8500_data->gpadc = ab8500_gpadc_get("ab8500-gpadc.0");
- if (IS_ERR(ab8500_data->gpadc))
- return PTR_ERR(ab8500_data->gpadc);
- ab8500_data->btemp = ab8500_btemp_get();
- if (IS_ERR(ab8500_data->btemp))
- return PTR_ERR(ab8500_data->btemp);
- INIT_DELAYED_WORK(&ab8500_data->power_off_work,
- ab8500_thermal_power_off);
- ab8500_data->cfg.vcc = THERMAL_VCC;
- ab8500_data->cfg.r_up = PULL_UP_RESISTOR;
- ab8500_data->cfg.temp_tbl = ab8500_temp_tbl_a_thermistor;
- ab8500_data->cfg.tbl_sz = ab8500_temp_tbl_a_size;
- data->plat_data = ab8500_data;
- /*
- * ADC_AUX1 and ADC_AUX2, connected to external NTC
- * BTEMP_BALL and BAT_CTRL, fixed usage
- */
- data->gpadc_addr[0] = ADC_AUX1;
- data->gpadc_addr[1] = ADC_AUX2;
- data->gpadc_addr[2] = BTEMP_BALL;
- data->gpadc_addr[3] = BAT_CTRL;
- data->monitored_sensors = NUM_MONITORED_SENSORS;
- data->ops.read_sensor = ab8500_read_sensor;
- data->ops.irq_handler = ab8500_temp_irq_handler;
- data->ops.show_name = ab8500_show_name;
- data->ops.show_label = ab8500_show_label;
- data->ops.is_visible = NULL;
- return 0;
- }
- EXPORT_SYMBOL(abx500_hwmon_init);
- MODULE_AUTHOR("Hongbo Zhang <hongbo.zhang@linaro.org>");
- MODULE_DESCRIPTION("AB8500 temperature driver");
- MODULE_LICENSE("GPL");
|