123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491
  1. Generic Thermal Sysfs driver How To
  2. ===================================
  3. Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
  4. Updated: 2 January 2008
  5. Copyright (c) 2008 Intel Corporation
  6. 0. Introduction
  7. The generic thermal sysfs provides a set of interfaces for thermal zone
  8. devices (sensors) and thermal cooling devices (fan, processor...) to register
  9. with the thermal management solution and to be a part of it.
  10. This how-to focuses on enabling new thermal zone and cooling devices to
  11. participate in thermal management.
  12. This solution is platform independent and any type of thermal zone devices
  13. and cooling devices should be able to make use of the infrastructure.
  14. The main task of the thermal sysfs driver is to expose thermal zone attributes
  15. as well as cooling device attributes to the user space.
  16. An intelligent thermal management application can make decisions based on
  17. inputs from thermal zone attributes (the current temperature and trip point
  18. temperature) and throttle appropriate devices.
  19. [0-*] denotes any positive number starting from 0
  20. [1-*] denotes any positive number starting from 1
  21. 1. thermal sysfs driver interface functions
  22. 1.1 thermal zone device interface
  23. 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
  24. int trips, int mask, void *devdata,
  25. struct thermal_zone_device_ops *ops,
  26. const struct thermal_zone_params *tzp,
  27. int passive_delay, int polling_delay))
  28. This interface function adds a new thermal zone device (sensor) to
  29. /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
  30. thermal cooling devices registered at the same time.
  31. type: the thermal zone type.
  32. trips: the total number of trip points this thermal zone supports.
  33. mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
  34. devdata: device private data
  35. ops: thermal zone device call-backs.
  36. .bind: bind the thermal zone device with a thermal cooling device.
  37. .unbind: unbind the thermal zone device with a thermal cooling device.
  38. .get_temp: get the current temperature of the thermal zone.
  39. .get_mode: get the current mode (enabled/disabled) of the thermal zone.
  40. - "enabled" means the kernel thermal management is enabled.
  41. - "disabled" will prevent kernel thermal driver action upon trip points
  42. so that user applications can take charge of thermal management.
  43. .set_mode: set the mode (enabled/disabled) of the thermal zone.
  44. .get_trip_type: get the type of certain trip point.
  45. .get_trip_temp: get the temperature above which the certain trip point
  46. will be fired.
  47. .set_emul_temp: set the emulation temperature which helps in debugging
  48. different threshold temperature points.
  49. tzp: thermal zone platform parameters.
  50. passive_delay: number of milliseconds to wait between polls when
  51. performing passive cooling.
  52. polling_delay: number of milliseconds to wait between polls when checking
  53. whether trip points have been crossed (0 for interrupt driven systems).
  54. 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
  55. This interface function removes the thermal zone device.
  56. It deletes the corresponding entry form /sys/class/thermal folder and
  57. unbind all the thermal cooling devices it uses.
  58. 1.2 thermal cooling device interface
  59. 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
  60. void *devdata, struct thermal_cooling_device_ops *)
  61. This interface function adds a new thermal cooling device (fan/processor/...)
  62. to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
  63. to all the thermal zone devices register at the same time.
  64. name: the cooling device name.
  65. devdata: device private data.
  66. ops: thermal cooling devices call-backs.
  67. .get_max_state: get the Maximum throttle state of the cooling device.
  68. .get_cur_state: get the Current throttle state of the cooling device.
  69. .set_cur_state: set the Current throttle state of the cooling device.
  70. 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
  71. This interface function remove the thermal cooling device.
  72. It deletes the corresponding entry form /sys/class/thermal folder and
  73. unbind itself from all the thermal zone devices using it.
  74. 1.3 interface for binding a thermal zone device with a thermal cooling device
  75. 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
  76. int trip, struct thermal_cooling_device *cdev,
  77. unsigned long upper, unsigned long lower, unsigned int weight);
  78. This interface function bind a thermal cooling device to the certain trip
  79. point of a thermal zone device.
  80. This function is usually called in the thermal zone device .bind callback.
  81. tz: the thermal zone device
  82. cdev: thermal cooling device
  83. trip: indicates which trip point the cooling devices is associated with
  84. in this thermal zone.
  85. upper:the Maximum cooling state for this trip point.
  86. THERMAL_NO_LIMIT means no upper limit,
  87. and the cooling device can be in max_state.
  88. lower:the Minimum cooling state can be used for this trip point.
  89. THERMAL_NO_LIMIT means no lower limit,
  90. and the cooling device can be in cooling state 0.
  91. weight: the influence of this cooling device in this thermal
  92. zone. See 1.4.1 below for more information.
  93. 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
  94. int trip, struct thermal_cooling_device *cdev);
  95. This interface function unbind a thermal cooling device from the certain
  96. trip point of a thermal zone device. This function is usually called in
  97. the thermal zone device .unbind callback.
  98. tz: the thermal zone device
  99. cdev: thermal cooling device
  100. trip: indicates which trip point the cooling devices is associated with
  101. in this thermal zone.
  102. 1.4 Thermal Zone Parameters
  103. 1.4.1 struct thermal_bind_params
  104. This structure defines the following parameters that are used to bind
  105. a zone with a cooling device for a particular trip point.
  106. .cdev: The cooling device pointer
  107. .weight: The 'influence' of a particular cooling device on this
  108. zone. This is relative to the rest of the cooling
  109. devices. For example, if all cooling devices have a
  110. weight of 1, then they all contribute the same. You can
  111. use percentages if you want, but it's not mandatory. A
  112. weight of 0 means that this cooling device doesn't
  113. contribute to the cooling of this zone unless all cooling
  114. devices have a weight of 0. If all weights are 0, then
  115. they all contribute the same.
  116. .trip_mask:This is a bit mask that gives the binding relation between
  117. this thermal zone and cdev, for a particular trip point.
  118. If nth bit is set, then the cdev and thermal zone are bound
  119. for trip point n.
  120. .limits: This is an array of cooling state limits. Must have exactly
  121. 2 * thermal_zone.number_of_trip_points. It is an array consisting
  122. of tuples <lower-state upper-state> of state limits. Each trip
  123. will be associated with one state limit tuple when binding.
  124. A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
  125. on all trips. These limits are used when binding a cdev to a
  126. trip point.
  127. .match: This call back returns success(0) if the 'tz and cdev' need to
  128. be bound, as per platform data.
  129. 1.4.2 struct thermal_zone_params
  130. This structure defines the platform level parameters for a thermal zone.
  131. This data, for each thermal zone should come from the platform layer.
  132. This is an optional feature where some platforms can choose not to
  133. provide this data.
  134. .governor_name: Name of the thermal governor used for this zone
  135. .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
  136. is required. when no_hwmon == false, a hwmon sysfs interface
  137. will be created. when no_hwmon == true, nothing will be done.
  138. In case the thermal_zone_params is NULL, the hwmon interface
  139. will be created (for backward compatibility).
  140. .num_tbps: Number of thermal_bind_params entries for this zone
  141. .tbp: thermal_bind_params entries
  142. 2. sysfs attributes structure
  143. RO read only value
  144. RW read/write value
  145. Thermal sysfs attributes will be represented under /sys/class/thermal.
  146. Hwmon sysfs I/F extension is also available under /sys/class/hwmon
  147. if hwmon is compiled in or built as a module.
  148. Thermal zone device sys I/F, created once it's registered:
  149. /sys/class/thermal/thermal_zone[0-*]:
  150. |---type: Type of the thermal zone
  151. |---temp: Current temperature
  152. |---mode: Working mode of the thermal zone
  153. |---policy: Thermal governor used for this zone
  154. |---trip_point_[0-*]_temp: Trip point temperature
  155. |---trip_point_[0-*]_type: Trip point type
  156. |---trip_point_[0-*]_hyst: Hysteresis value for this trip point
  157. |---emul_temp: Emulated temperature set node
  158. |---sustainable_power: Sustainable dissipatable power
  159. |---k_po: Proportional term during temperature overshoot
  160. |---k_pu: Proportional term during temperature undershoot
  161. |---k_i: PID's integral term in the power allocator gov
  162. |---k_d: PID's derivative term in the power allocator
  163. |---integral_cutoff: Offset above which errors are accumulated
  164. |---slope: Slope constant applied as linear extrapolation
  165. |---offset: Offset constant applied as linear extrapolation
  166. Thermal cooling device sys I/F, created once it's registered:
  167. /sys/class/thermal/cooling_device[0-*]:
  168. |---type: Type of the cooling device(processor/fan/...)
  169. |---max_state: Maximum cooling state of the cooling device
  170. |---cur_state: Current cooling state of the cooling device
  171. Then next two dynamic attributes are created/removed in pairs. They represent
  172. the relationship between a thermal zone and its associated cooling device.
  173. They are created/removed for each successful execution of
  174. thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
  175. /sys/class/thermal/thermal_zone[0-*]:
  176. |---cdev[0-*]: [0-*]th cooling device in current thermal zone
  177. |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
  178. |---cdev[0-*]_weight: Influence of the cooling device in
  179. this thermal zone
  180. Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
  181. the generic thermal driver also creates a hwmon sysfs I/F for each _type_
  182. of thermal zone device. E.g. the generic thermal driver registers one hwmon
  183. class device and build the associated hwmon sysfs I/F for all the registered
  184. ACPI thermal zones.
  185. /sys/class/hwmon/hwmon[0-*]:
  186. |---name: The type of the thermal zone devices
  187. |---temp[1-*]_input: The current temperature of thermal zone [1-*]
  188. |---temp[1-*]_critical: The critical trip point of thermal zone [1-*]
  189. Please read Documentation/hwmon/sysfs-interface for additional information.
  190. ***************************
  191. * Thermal zone attributes *
  192. ***************************
  193. type
  194. Strings which represent the thermal zone type.
  195. This is given by thermal zone driver as part of registration.
  196. E.g: "acpitz" indicates it's an ACPI thermal device.
  197. In order to keep it consistent with hwmon sys attribute; this should
  198. be a short, lowercase string, not containing spaces nor dashes.
  199. RO, Required
  200. temp
  201. Current temperature as reported by thermal zone (sensor).
  202. Unit: millidegree Celsius
  203. RO, Required
  204. mode
  205. One of the predefined values in [enabled, disabled].
  206. This file gives information about the algorithm that is currently
  207. managing the thermal zone. It can be either default kernel based
  208. algorithm or user space application.
  209. enabled = enable Kernel Thermal management.
  210. disabled = Preventing kernel thermal zone driver actions upon
  211. trip points so that user application can take full
  212. charge of the thermal management.
  213. RW, Optional
  214. policy
  215. One of the various thermal governors used for a particular zone.
  216. RW, Required
  217. trip_point_[0-*]_temp
  218. The temperature above which trip point will be fired.
  219. Unit: millidegree Celsius
  220. RO, Optional
  221. trip_point_[0-*]_type
  222. Strings which indicate the type of the trip point.
  223. E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
  224. thermal zone.
  225. RO, Optional
  226. trip_point_[0-*]_hyst
  227. The hysteresis value for a trip point, represented as an integer
  228. Unit: Celsius
  229. RW, Optional
  230. cdev[0-*]
  231. Sysfs link to the thermal cooling device node where the sys I/F
  232. for cooling device throttling control represents.
  233. RO, Optional
  234. cdev[0-*]_trip_point
  235. The trip point with which cdev[0-*] is associated in this thermal
  236. zone; -1 means the cooling device is not associated with any trip
  237. point.
  238. RO, Optional
  239. cdev[0-*]_weight
  240. The influence of cdev[0-*] in this thermal zone. This value
  241. is relative to the rest of cooling devices in the thermal
  242. zone. For example, if a cooling device has a weight double
  243. than that of other, it's twice as effective in cooling the
  244. thermal zone.
  245. RW, Optional
  246. passive
  247. Attribute is only present for zones in which the passive cooling
  248. policy is not supported by native thermal driver. Default is zero
  249. and can be set to a temperature (in millidegrees) to enable a
  250. passive trip point for the zone. Activation is done by polling with
  251. an interval of 1 second.
  252. Unit: millidegrees Celsius
  253. Valid values: 0 (disabled) or greater than 1000
  254. RW, Optional
  255. emul_temp
  256. Interface to set the emulated temperature method in thermal zone
  257. (sensor). After setting this temperature, the thermal zone may pass
  258. this temperature to platform emulation function if registered or
  259. cache it locally. This is useful in debugging different temperature
  260. threshold and its associated cooling action. This is write only node
  261. and writing 0 on this node should disable emulation.
  262. Unit: millidegree Celsius
  263. WO, Optional
  264. WARNING: Be careful while enabling this option on production systems,
  265. because userland can easily disable the thermal policy by simply
  266. flooding this sysfs node with low temperature values.
  267. sustainable_power
  268. An estimate of the sustained power that can be dissipated by
  269. the thermal zone. Used by the power allocator governor. For
  270. more information see Documentation/thermal/power_allocator.txt
  271. Unit: milliwatts
  272. RW, Optional
  273. k_po
  274. The proportional term of the power allocator governor's PID
  275. controller during temperature overshoot. Temperature overshoot
  276. is when the current temperature is above the "desired
  277. temperature" trip point. For more information see
  278. Documentation/thermal/power_allocator.txt
  279. RW, Optional
  280. k_pu
  281. The proportional term of the power allocator governor's PID
  282. controller during temperature undershoot. Temperature undershoot
  283. is when the current temperature is below the "desired
  284. temperature" trip point. For more information see
  285. Documentation/thermal/power_allocator.txt
  286. RW, Optional
  287. k_i
  288. The integral term of the power allocator governor's PID
  289. controller. This term allows the PID controller to compensate
  290. for long term drift. For more information see
  291. Documentation/thermal/power_allocator.txt
  292. RW, Optional
  293. k_d
  294. The derivative term of the power allocator governor's PID
  295. controller. For more information see
  296. Documentation/thermal/power_allocator.txt
  297. RW, Optional
  298. integral_cutoff
  299. Temperature offset from the desired temperature trip point
  300. above which the integral term of the power allocator
  301. governor's PID controller starts accumulating errors. For
  302. example, if integral_cutoff is 0, then the integral term only
  303. accumulates error when temperature is above the desired
  304. temperature trip point. For more information see
  305. Documentation/thermal/power_allocator.txt
  306. RW, Optional
  307. slope
  308. The slope constant used in a linear extrapolation model
  309. to determine a hotspot temperature based off the sensor's
  310. raw readings. It is up to the device driver to determine
  311. the usage of these values.
  312. RW, Optional
  313. offset
  314. The offset constant used in a linear extrapolation model
  315. to determine a hotspot temperature based off the sensor's
  316. raw readings. It is up to the device driver to determine
  317. the usage of these values.
  318. RW, Optional
  319. *****************************
  320. * Cooling device attributes *
  321. *****************************
  322. type
  323. String which represents the type of device, e.g:
  324. - for generic ACPI: should be "Fan", "Processor" or "LCD"
  325. - for memory controller device on intel_menlow platform:
  326. should be "Memory controller".
  327. RO, Required
  328. max_state
  329. The maximum permissible cooling state of this cooling device.
  330. RO, Required
  331. cur_state
  332. The current cooling state of this cooling device.
  333. The value can any integer numbers between 0 and max_state:
  334. - cur_state == 0 means no cooling
  335. - cur_state == max_state means the maximum cooling.
  336. RW, Required
  337. 3. A simple implementation
  338. ACPI thermal zone may support multiple trip points like critical, hot,
  339. passive, active. If an ACPI thermal zone supports critical, passive,
  340. active[0] and active[1] at the same time, it may register itself as a
  341. thermal_zone_device (thermal_zone1) with 4 trip points in all.
  342. It has one processor and one fan, which are both registered as
  343. thermal_cooling_device. Both are considered to have the same
  344. effectiveness in cooling the thermal zone.
  345. If the processor is listed in _PSL method, and the fan is listed in _AL0
  346. method, the sys I/F structure will be built like this:
  347. /sys/class/thermal:
  348. |thermal_zone1:
  349. |---type: acpitz
  350. |---temp: 37000
  351. |---mode: enabled
  352. |---policy: step_wise
  353. |---trip_point_0_temp: 100000
  354. |---trip_point_0_type: critical
  355. |---trip_point_1_temp: 80000
  356. |---trip_point_1_type: passive
  357. |---trip_point_2_temp: 70000
  358. |---trip_point_2_type: active0
  359. |---trip_point_3_temp: 60000
  360. |---trip_point_3_type: active1
  361. |---cdev0: --->/sys/class/thermal/cooling_device0
  362. |---cdev0_trip_point: 1 /* cdev0 can be used for passive */
  363. |---cdev0_weight: 1024
  364. |---cdev1: --->/sys/class/thermal/cooling_device3
  365. |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
  366. |---cdev1_weight: 1024
  367. |cooling_device0:
  368. |---type: Processor
  369. |---max_state: 8
  370. |---cur_state: 0
  371. |cooling_device3:
  372. |---type: Fan
  373. |---max_state: 2
  374. |---cur_state: 0
  375. /sys/class/hwmon:
  376. |hwmon0:
  377. |---name: acpitz
  378. |---temp1_input: 37000
  379. |---temp1_crit: 100000
  380. 4. Event Notification
  381. The framework includes a simple notification mechanism, in the form of a
  382. netlink event. Netlink socket initialization is done during the _init_
  383. of the framework. Drivers which intend to use the notification mechanism
  384. just need to call thermal_generate_netlink_event() with two arguments viz
  385. (originator, event). The originator is a pointer to struct thermal_zone_device
  386. from where the event has been originated. An integer which represents the
  387. thermal zone device will be used in the message to identify the zone. The
  388. event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
  389. THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
  390. crosses any of the configured thresholds.
  391. 5. Export Symbol APIs:
  392. 5.1: get_tz_trend:
  393. This function returns the trend of a thermal zone, i.e the rate of change
  394. of temperature of the thermal zone. Ideally, the thermal sensor drivers
  395. are supposed to implement the callback. If they don't, the thermal
  396. framework calculated the trend by comparing the previous and the current
  397. temperature values.
  398. 5.2:get_thermal_instance:
  399. This function returns the thermal_instance corresponding to a given
  400. {thermal_zone, cooling_device, trip_point} combination. Returns NULL
  401. if such an instance does not exist.
  402. 5.3:thermal_notify_framework:
  403. This function handles the trip events from sensor drivers. It starts
  404. throttling the cooling devices according to the policy configured.
  405. For CRITICAL and HOT trip points, this notifies the respective drivers,
  406. and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
  407. The throttling policy is based on the configured platform data; if no
  408. platform data is provided, this uses the step_wise throttling policy.
  409. 5.4:thermal_cdev_update:
  410. This function serves as an arbitrator to set the state of a cooling
  411. device. It sets the cooling device to the deepest cooling state if
  412. possible.