123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808809810811812813814815816817818819820821 |
- /*
- * linux/drivers/thermal/cpu_cooling.c
- *
- * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
- * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
- *
- * Copyright (C) 2014 Viresh Kumar <viresh.kumar@linaro.org>
- *
- * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- * This program is free software; you can redistribute it and/or modify
- * it under the terms of the GNU General Public License as published by
- * the Free Software Foundation; version 2 of the License.
- *
- * This program is distributed in the hope that it will be useful, but
- * WITHOUT ANY WARRANTY; without even the implied warranty of
- * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
- * General Public License for more details.
- *
- * You should have received a copy of the GNU General Public License along
- * with this program; if not, write to the Free Software Foundation, Inc.,
- * 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
- *
- * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- */
- #include <linux/module.h>
- #include <linux/thermal.h>
- #include <linux/cpufreq.h>
- #include <linux/err.h>
- #include <linux/idr.h>
- #include <linux/pm_opp.h>
- #include <linux/slab.h>
- #include <linux/cpu.h>
- #include <linux/cpu_cooling.h>
- #include <trace/events/thermal.h>
- /*
- * Cooling state <-> CPUFreq frequency
- *
- * Cooling states are translated to frequencies throughout this driver and this
- * is the relation between them.
- *
- * Highest cooling state corresponds to lowest possible frequency.
- *
- * i.e.
- * level 0 --> 1st Max Freq
- * level 1 --> 2nd Max Freq
- * ...
- */
- /**
- * struct freq_table - frequency table along with power entries
- * @frequency: frequency in KHz
- * @power: power in mW
- *
- * This structure is built when the cooling device registers and helps
- * in translating frequency to power and vice versa.
- */
- struct freq_table {
- u32 frequency;
- u32 power;
- };
- /**
- * struct time_in_idle - Idle time stats
- * @time: previous reading of the absolute time that this cpu was idle
- * @timestamp: wall time of the last invocation of get_cpu_idle_time_us()
- */
- struct time_in_idle {
- u64 time;
- u64 timestamp;
- };
- /**
- * struct cpufreq_cooling_device - data for cooling device with cpufreq
- * @id: unique integer value corresponding to each cpufreq_cooling_device
- * registered.
- * @last_load: load measured by the latest call to cpufreq_get_requested_power()
- * @cpufreq_state: integer value representing the current state of cpufreq
- * cooling devices.
- * @clipped_freq: integer value representing the absolute value of the clipped
- * frequency.
- * @max_level: maximum cooling level. One less than total number of valid
- * cpufreq frequencies.
- * @freq_table: Freq table in descending order of frequencies
- * @cdev: thermal_cooling_device pointer to keep track of the
- * registered cooling device.
- * @policy: cpufreq policy.
- * @node: list_head to link all cpufreq_cooling_device together.
- * @idle_time: idle time stats
- *
- * This structure is required for keeping information of each registered
- * cpufreq_cooling_device.
- */
- struct cpufreq_cooling_device {
- int id;
- u32 last_load;
- unsigned int cpufreq_state;
- unsigned int clipped_freq;
- unsigned int max_level;
- struct freq_table *freq_table; /* In descending order */
- struct thermal_cooling_device *cdev;
- struct cpufreq_policy *policy;
- struct list_head node;
- struct time_in_idle *idle_time;
- };
- static DEFINE_IDA(cpufreq_ida);
- static DEFINE_MUTEX(cooling_list_lock);
- static LIST_HEAD(cpufreq_cdev_list);
- /* Below code defines functions to be used for cpufreq as cooling device */
- /**
- * get_level: Find the level for a particular frequency
- * @cpufreq_cdev: cpufreq_cdev for which the property is required
- * @freq: Frequency
- *
- * Return: level corresponding to the frequency.
- */
- static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
- unsigned int freq)
- {
- struct freq_table *freq_table = cpufreq_cdev->freq_table;
- unsigned long level;
- for (level = 1; level <= cpufreq_cdev->max_level; level++)
- if (freq > freq_table[level].frequency)
- break;
- return level - 1;
- }
- /**
- * cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
- * @nb: struct notifier_block * with callback info.
- * @event: value showing cpufreq event for which this function invoked.
- * @data: callback-specific data
- *
- * Callback to hijack the notification on cpufreq policy transition.
- * Every time there is a change in policy, we will intercept and
- * update the cpufreq policy with thermal constraints.
- *
- * Return: 0 (success)
- */
- static int cpufreq_thermal_notifier(struct notifier_block *nb,
- unsigned long event, void *data)
- {
- struct cpufreq_policy *policy = data;
- unsigned long clipped_freq;
- struct cpufreq_cooling_device *cpufreq_cdev;
- if (event != CPUFREQ_ADJUST)
- return NOTIFY_DONE;
- mutex_lock(&cooling_list_lock);
- list_for_each_entry(cpufreq_cdev, &cpufreq_cdev_list, node) {
- /*
- * A new copy of the policy is sent to the notifier and can't
- * compare that directly.
- */
- if (policy->cpu != cpufreq_cdev->policy->cpu)
- continue;
- /*
- * policy->max is the maximum allowed frequency defined by user
- * and clipped_freq is the maximum that thermal constraints
- * allow.
- *
- * If clipped_freq is lower than policy->max, then we need to
- * readjust policy->max.
- *
- * But, if clipped_freq is greater than policy->max, we don't
- * need to do anything.
- */
- clipped_freq = cpufreq_cdev->clipped_freq;
- if (policy->max > clipped_freq)
- cpufreq_verify_within_limits(policy, 0, clipped_freq);
- break;
- }
- mutex_unlock(&cooling_list_lock);
- return NOTIFY_OK;
- }
- /**
- * update_freq_table() - Update the freq table with power numbers
- * @cpufreq_cdev: the cpufreq cooling device in which to update the table
- * @capacitance: dynamic power coefficient for these cpus
- *
- * Update the freq table with power numbers. This table will be used in
- * cpu_power_to_freq() and cpu_freq_to_power() to convert between power and
- * frequency efficiently. Power is stored in mW, frequency in KHz. The
- * resulting table is in descending order.
- *
- * Return: 0 on success, -EINVAL if there are no OPPs for any CPUs,
- * or -ENOMEM if we run out of memory.
- */
- static int update_freq_table(struct cpufreq_cooling_device *cpufreq_cdev,
- u32 capacitance)
- {
- struct freq_table *freq_table = cpufreq_cdev->freq_table;
- struct dev_pm_opp *opp;
- struct device *dev = NULL;
- int num_opps = 0, cpu = cpufreq_cdev->policy->cpu, i;
- dev = get_cpu_device(cpu);
- if (unlikely(!dev)) {
- dev_warn(&cpufreq_cdev->cdev->device,
- "No cpu device for cpu %d\n", cpu);
- return -ENODEV;
- }
- num_opps = dev_pm_opp_get_opp_count(dev);
- if (num_opps < 0)
- return num_opps;
- /*
- * The cpufreq table is also built from the OPP table and so the count
- * should match.
- */
- if (num_opps != cpufreq_cdev->max_level + 1) {
- dev_warn(dev, "Number of OPPs not matching with max_levels\n");
- return -EINVAL;
- }
- for (i = 0; i <= cpufreq_cdev->max_level; i++) {
- unsigned long freq = freq_table[i].frequency * 1000;
- u32 freq_mhz = freq_table[i].frequency / 1000;
- u64 power;
- u32 voltage_mv;
- /*
- * Find ceil frequency as 'freq' may be slightly lower than OPP
- * freq due to truncation while converting to kHz.
- */
- opp = dev_pm_opp_find_freq_ceil(dev, &freq);
- if (IS_ERR(opp)) {
- dev_err(dev, "failed to get opp for %lu frequency\n",
- freq);
- return -EINVAL;
- }
- voltage_mv = dev_pm_opp_get_voltage(opp) / 1000;
- dev_pm_opp_put(opp);
- /*
- * Do the multiplication with MHz and millivolt so as
- * to not overflow.
- */
- power = (u64)capacitance * freq_mhz * voltage_mv * voltage_mv;
- do_div(power, 1000000000);
- /* power is stored in mW */
- freq_table[i].power = power;
- }
- return 0;
- }
- static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev,
- u32 freq)
- {
- int i;
- struct freq_table *freq_table = cpufreq_cdev->freq_table;
- for (i = 1; i <= cpufreq_cdev->max_level; i++)
- if (freq > freq_table[i].frequency)
- break;
- return freq_table[i - 1].power;
- }
- static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev,
- u32 power)
- {
- int i;
- struct freq_table *freq_table = cpufreq_cdev->freq_table;
- for (i = 1; i <= cpufreq_cdev->max_level; i++)
- if (power > freq_table[i].power)
- break;
- return freq_table[i - 1].frequency;
- }
- /**
- * get_load() - get load for a cpu since last updated
- * @cpufreq_cdev: &struct cpufreq_cooling_device for this cpu
- * @cpu: cpu number
- * @cpu_idx: index of the cpu in time_in_idle*
- *
- * Return: The average load of cpu @cpu in percentage since this
- * function was last called.
- */
- static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
- int cpu_idx)
- {
- u32 load;
- u64 now, now_idle, delta_time, delta_idle;
- struct time_in_idle *idle_time = &cpufreq_cdev->idle_time[cpu_idx];
- now_idle = get_cpu_idle_time(cpu, &now, 0);
- delta_idle = now_idle - idle_time->time;
- delta_time = now - idle_time->timestamp;
- if (delta_time <= delta_idle)
- load = 0;
- else
- load = div64_u64(100 * (delta_time - delta_idle), delta_time);
- idle_time->time = now_idle;
- idle_time->timestamp = now;
- return load;
- }
- /**
- * get_dynamic_power() - calculate the dynamic power
- * @cpufreq_cdev: &cpufreq_cooling_device for this cdev
- * @freq: current frequency
- *
- * Return: the dynamic power consumed by the cpus described by
- * @cpufreq_cdev.
- */
- static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
- unsigned long freq)
- {
- u32 raw_cpu_power;
- raw_cpu_power = cpu_freq_to_power(cpufreq_cdev, freq);
- return (raw_cpu_power * cpufreq_cdev->last_load) / 100;
- }
- /* cpufreq cooling device callback functions are defined below */
- /**
- * cpufreq_get_max_state - callback function to get the max cooling state.
- * @cdev: thermal cooling device pointer.
- * @state: fill this variable with the max cooling state.
- *
- * Callback for the thermal cooling device to return the cpufreq
- * max cooling state.
- *
- * Return: 0 on success, an error code otherwise.
- */
- static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
- unsigned long *state)
- {
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
- *state = cpufreq_cdev->max_level;
- return 0;
- }
- /**
- * cpufreq_get_cur_state - callback function to get the current cooling state.
- * @cdev: thermal cooling device pointer.
- * @state: fill this variable with the current cooling state.
- *
- * Callback for the thermal cooling device to return the cpufreq
- * current cooling state.
- *
- * Return: 0 on success, an error code otherwise.
- */
- static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
- unsigned long *state)
- {
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
- *state = cpufreq_cdev->cpufreq_state;
- return 0;
- }
- /**
- * cpufreq_set_cur_state - callback function to set the current cooling state.
- * @cdev: thermal cooling device pointer.
- * @state: set this variable to the current cooling state.
- *
- * Callback for the thermal cooling device to change the cpufreq
- * current cooling state.
- *
- * Return: 0 on success, an error code otherwise.
- */
- static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
- unsigned long state)
- {
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
- unsigned int clip_freq;
- /* Request state should be less than max_level */
- if (WARN_ON(state > cpufreq_cdev->max_level))
- return -EINVAL;
- /* Check if the old cooling action is same as new cooling action */
- if (cpufreq_cdev->cpufreq_state == state)
- return 0;
- clip_freq = cpufreq_cdev->freq_table[state].frequency;
- cpufreq_cdev->cpufreq_state = state;
- cpufreq_cdev->clipped_freq = clip_freq;
- cpufreq_update_policy(cpufreq_cdev->policy->cpu);
- return 0;
- }
- /**
- * cpufreq_get_requested_power() - get the current power
- * @cdev: &thermal_cooling_device pointer
- * @tz: a valid thermal zone device pointer
- * @power: pointer in which to store the resulting power
- *
- * Calculate the current power consumption of the cpus in milliwatts
- * and store it in @power. This function should actually calculate
- * the requested power, but it's hard to get the frequency that
- * cpufreq would have assigned if there were no thermal limits.
- * Instead, we calculate the current power on the assumption that the
- * immediate future will look like the immediate past.
- *
- * We use the current frequency and the average load since this
- * function was last called. In reality, there could have been
- * multiple opps since this function was last called and that affects
- * the load calculation. While it's not perfectly accurate, this
- * simplification is good enough and works. REVISIT this, as more
- * complex code may be needed if experiments show that it's not
- * accurate enough.
- *
- * Return: 0 on success, -E* if getting the static power failed.
- */
- static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
- struct thermal_zone_device *tz,
- u32 *power)
- {
- unsigned long freq;
- int i = 0, cpu;
- u32 total_load = 0;
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
- struct cpufreq_policy *policy = cpufreq_cdev->policy;
- u32 *load_cpu = NULL;
- freq = cpufreq_quick_get(policy->cpu);
- if (trace_thermal_power_cpu_get_power_enabled()) {
- u32 ncpus = cpumask_weight(policy->related_cpus);
- load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL);
- }
- for_each_cpu(cpu, policy->related_cpus) {
- u32 load;
- if (cpu_online(cpu))
- load = get_load(cpufreq_cdev, cpu, i);
- else
- load = 0;
- total_load += load;
- if (load_cpu)
- load_cpu[i] = load;
- i++;
- }
- cpufreq_cdev->last_load = total_load;
- *power = get_dynamic_power(cpufreq_cdev, freq);
- if (load_cpu) {
- trace_thermal_power_cpu_get_power(policy->related_cpus, freq,
- load_cpu, i, *power);
- kfree(load_cpu);
- }
- return 0;
- }
- /**
- * cpufreq_state2power() - convert a cpu cdev state to power consumed
- * @cdev: &thermal_cooling_device pointer
- * @tz: a valid thermal zone device pointer
- * @state: cooling device state to be converted
- * @power: pointer in which to store the resulting power
- *
- * Convert cooling device state @state into power consumption in
- * milliwatts assuming 100% load. Store the calculated power in
- * @power.
- *
- * Return: 0 on success, -EINVAL if the cooling device state could not
- * be converted into a frequency or other -E* if there was an error
- * when calculating the static power.
- */
- static int cpufreq_state2power(struct thermal_cooling_device *cdev,
- struct thermal_zone_device *tz,
- unsigned long state, u32 *power)
- {
- unsigned int freq, num_cpus;
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
- /* Request state should be less than max_level */
- if (WARN_ON(state > cpufreq_cdev->max_level))
- return -EINVAL;
- num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus);
- freq = cpufreq_cdev->freq_table[state].frequency;
- *power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus;
- return 0;
- }
- /**
- * cpufreq_power2state() - convert power to a cooling device state
- * @cdev: &thermal_cooling_device pointer
- * @tz: a valid thermal zone device pointer
- * @power: power in milliwatts to be converted
- * @state: pointer in which to store the resulting state
- *
- * Calculate a cooling device state for the cpus described by @cdev
- * that would allow them to consume at most @power mW and store it in
- * @state. Note that this calculation depends on external factors
- * such as the cpu load or the current static power. Calling this
- * function with the same power as input can yield different cooling
- * device states depending on those external factors.
- *
- * Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if
- * the calculated frequency could not be converted to a valid state.
- * The latter should not happen unless the frequencies available to
- * cpufreq have changed since the initialization of the cpu cooling
- * device.
- */
- static int cpufreq_power2state(struct thermal_cooling_device *cdev,
- struct thermal_zone_device *tz, u32 power,
- unsigned long *state)
- {
- unsigned int cur_freq, target_freq;
- u32 last_load, normalised_power;
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
- struct cpufreq_policy *policy = cpufreq_cdev->policy;
- cur_freq = cpufreq_quick_get(policy->cpu);
- power = power > 0 ? power : 0;
- last_load = cpufreq_cdev->last_load ?: 1;
- normalised_power = (power * 100) / last_load;
- target_freq = cpu_power_to_freq(cpufreq_cdev, normalised_power);
- *state = get_level(cpufreq_cdev, target_freq);
- trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state,
- power);
- return 0;
- }
- /* Bind cpufreq callbacks to thermal cooling device ops */
- static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
- .get_max_state = cpufreq_get_max_state,
- .get_cur_state = cpufreq_get_cur_state,
- .set_cur_state = cpufreq_set_cur_state,
- };
- static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
- .get_max_state = cpufreq_get_max_state,
- .get_cur_state = cpufreq_get_cur_state,
- .set_cur_state = cpufreq_set_cur_state,
- .get_requested_power = cpufreq_get_requested_power,
- .state2power = cpufreq_state2power,
- .power2state = cpufreq_power2state,
- };
- /* Notifier for cpufreq policy change */
- static struct notifier_block thermal_cpufreq_notifier_block = {
- .notifier_call = cpufreq_thermal_notifier,
- };
- static unsigned int find_next_max(struct cpufreq_frequency_table *table,
- unsigned int prev_max)
- {
- struct cpufreq_frequency_table *pos;
- unsigned int max = 0;
- cpufreq_for_each_valid_entry(pos, table) {
- if (pos->frequency > max && pos->frequency < prev_max)
- max = pos->frequency;
- }
- return max;
- }
- /**
- * __cpufreq_cooling_register - helper function to create cpufreq cooling device
- * @np: a valid struct device_node to the cooling device device tree node
- * @policy: cpufreq policy
- * Normally this should be same as cpufreq policy->related_cpus.
- * @capacitance: dynamic power coefficient for these cpus
- *
- * This interface function registers the cpufreq cooling device with the name
- * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
- * cooling devices. It also gives the opportunity to link the cooling device
- * with a device tree node, in order to bind it via the thermal DT code.
- *
- * Return: a valid struct thermal_cooling_device pointer on success,
- * on failure, it returns a corresponding ERR_PTR().
- */
- static struct thermal_cooling_device *
- __cpufreq_cooling_register(struct device_node *np,
- struct cpufreq_policy *policy, u32 capacitance)
- {
- struct thermal_cooling_device *cdev;
- struct cpufreq_cooling_device *cpufreq_cdev;
- char dev_name[THERMAL_NAME_LENGTH];
- unsigned int freq, i, num_cpus;
- int ret;
- struct thermal_cooling_device_ops *cooling_ops;
- bool first;
- if (IS_ERR_OR_NULL(policy)) {
- pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy);
- return ERR_PTR(-EINVAL);
- }
- i = cpufreq_table_count_valid_entries(policy);
- if (!i) {
- pr_debug("%s: CPUFreq table not found or has no valid entries\n",
- __func__);
- return ERR_PTR(-ENODEV);
- }
- cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL);
- if (!cpufreq_cdev)
- return ERR_PTR(-ENOMEM);
- cpufreq_cdev->policy = policy;
- num_cpus = cpumask_weight(policy->related_cpus);
- cpufreq_cdev->idle_time = kcalloc(num_cpus,
- sizeof(*cpufreq_cdev->idle_time),
- GFP_KERNEL);
- if (!cpufreq_cdev->idle_time) {
- cdev = ERR_PTR(-ENOMEM);
- goto free_cdev;
- }
- /* max_level is an index, not a counter */
- cpufreq_cdev->max_level = i - 1;
- cpufreq_cdev->freq_table = kmalloc_array(i,
- sizeof(*cpufreq_cdev->freq_table),
- GFP_KERNEL);
- if (!cpufreq_cdev->freq_table) {
- cdev = ERR_PTR(-ENOMEM);
- goto free_idle_time;
- }
- ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL);
- if (ret < 0) {
- cdev = ERR_PTR(ret);
- goto free_table;
- }
- cpufreq_cdev->id = ret;
- snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
- cpufreq_cdev->id);
- /* Fill freq-table in descending order of frequencies */
- for (i = 0, freq = -1; i <= cpufreq_cdev->max_level; i++) {
- freq = find_next_max(policy->freq_table, freq);
- cpufreq_cdev->freq_table[i].frequency = freq;
- /* Warn for duplicate entries */
- if (!freq)
- pr_warn("%s: table has duplicate entries\n", __func__);
- else
- pr_debug("%s: freq:%u KHz\n", __func__, freq);
- }
- if (capacitance) {
- ret = update_freq_table(cpufreq_cdev, capacitance);
- if (ret) {
- cdev = ERR_PTR(ret);
- goto remove_ida;
- }
- cooling_ops = &cpufreq_power_cooling_ops;
- } else {
- cooling_ops = &cpufreq_cooling_ops;
- }
- cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
- cooling_ops);
- if (IS_ERR(cdev))
- goto remove_ida;
- cpufreq_cdev->clipped_freq = cpufreq_cdev->freq_table[0].frequency;
- cpufreq_cdev->cdev = cdev;
- mutex_lock(&cooling_list_lock);
- /* Register the notifier for first cpufreq cooling device */
- first = list_empty(&cpufreq_cdev_list);
- list_add(&cpufreq_cdev->node, &cpufreq_cdev_list);
- mutex_unlock(&cooling_list_lock);
- if (first)
- cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
- CPUFREQ_POLICY_NOTIFIER);
- return cdev;
- remove_ida:
- ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
- free_table:
- kfree(cpufreq_cdev->freq_table);
- free_idle_time:
- kfree(cpufreq_cdev->idle_time);
- free_cdev:
- kfree(cpufreq_cdev);
- return cdev;
- }
- /**
- * cpufreq_cooling_register - function to create cpufreq cooling device.
- * @policy: cpufreq policy
- *
- * This interface function registers the cpufreq cooling device with the name
- * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
- * cooling devices.
- *
- * Return: a valid struct thermal_cooling_device pointer on success,
- * on failure, it returns a corresponding ERR_PTR().
- */
- struct thermal_cooling_device *
- cpufreq_cooling_register(struct cpufreq_policy *policy)
- {
- return __cpufreq_cooling_register(NULL, policy, 0);
- }
- EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
- /**
- * of_cpufreq_cooling_register - function to create cpufreq cooling device.
- * @policy: cpufreq policy
- *
- * This interface function registers the cpufreq cooling device with the name
- * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
- * cooling devices. Using this API, the cpufreq cooling device will be
- * linked to the device tree node provided.
- *
- * Using this function, the cooling device will implement the power
- * extensions by using a simple cpu power model. The cpus must have
- * registered their OPPs using the OPP library.
- *
- * It also takes into account, if property present in policy CPU node, the
- * static power consumed by the cpu.
- *
- * Return: a valid struct thermal_cooling_device pointer on success,
- * and NULL on failure.
- */
- struct thermal_cooling_device *
- of_cpufreq_cooling_register(struct cpufreq_policy *policy)
- {
- struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
- struct thermal_cooling_device *cdev = NULL;
- u32 capacitance = 0;
- if (!np) {
- pr_err("cpu_cooling: OF node not available for cpu%d\n",
- policy->cpu);
- return NULL;
- }
- if (of_find_property(np, "#cooling-cells", NULL)) {
- of_property_read_u32(np, "dynamic-power-coefficient",
- &capacitance);
- cdev = __cpufreq_cooling_register(np, policy, capacitance);
- if (IS_ERR(cdev)) {
- pr_err("cpu_cooling: cpu%d is not running as cooling device: %ld\n",
- policy->cpu, PTR_ERR(cdev));
- cdev = NULL;
- }
- }
- of_node_put(np);
- return cdev;
- }
- EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
- /**
- * cpufreq_cooling_unregister - function to remove cpufreq cooling device.
- * @cdev: thermal cooling device pointer.
- *
- * This interface function unregisters the "thermal-cpufreq-%x" cooling device.
- */
- void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
- {
- struct cpufreq_cooling_device *cpufreq_cdev;
- bool last;
- if (!cdev)
- return;
- cpufreq_cdev = cdev->devdata;
- mutex_lock(&cooling_list_lock);
- list_del(&cpufreq_cdev->node);
- /* Unregister the notifier for the last cpufreq cooling device */
- last = list_empty(&cpufreq_cdev_list);
- mutex_unlock(&cooling_list_lock);
- if (last)
- cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
- CPUFREQ_POLICY_NOTIFIER);
- thermal_cooling_device_unregister(cpufreq_cdev->cdev);
- ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
- kfree(cpufreq_cdev->idle_time);
- kfree(cpufreq_cdev->freq_table);
- kfree(cpufreq_cdev);
- }
- EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);
|