  16. .\" .sp <n> insert n+1 empty lines
  17. .\" for manpage-specific macros, see man(7)
  18. .SH NAME
  19. jkmeter \- Jkmeter is a horizontal or vertical bargraph audio level meter for Jack Audio Connection Kit
  20. .SH SYNOPSIS
  21. .B jkmeter
  22. .RI [ options ]
  23. .br
  24. .SH DESCRIPTION
  25. This manual page documents briefly the
  26. .B jkmeter
  27. .PP
  28. .\" TeX users may be more comfortable with the \fB<whatever>\fP and
  29. .\" \fI<whatever>\fP escape sequences to invode bold face and italics,
  30. .\" respectively.
  31. This manual page was written for the Debian distribution because the original program does not have a manual page.
  32. .PP
  33. .\" TeX users may be more comfortable with the \fB<whatever>\fP and
  34. .\" \fI<whatever>\fP escape sequences to invode bold face and italics,
  35. .\" respectively.
  36. \fBjkmeter\fP is a horizontal or vertical bargraph level meter based on the ideas of mastering guru Bob Katz. <https://www.aes.org/technical/documentDownloads.cfm?docID=65>
  37. .br
  38. This meter displays both the true RMS level and the digital peak level.
  39. .SH OPTIONS
  40. .PP
  41. .B \ -h
  42. Display short info
  43. .PP
  44. .B \ -name <name>
  45. Name to use as jack client
  46. .PP
  47. .B \ -s <server>
  48. Jack server name
  49. .PP
  50. .B \ -g <geometry>
  51. Window position
  52. .PP
  53. .B \ -type <type>
  54. Meter type, k20 or k14 (k20)
  55. .PP
  56. .B \ -rate <rate>
  57. Update rate (30)
  58. .PP
  59. .B \ -A
  60. Ambisonic (4ch) mode
  61. .PP
  62. .B \ -C
  63. Add correlation meter
  64. .PP
  65. .B \ -V
  66. Vertical layout
  67. .PP
  68. .B \ -H
  69. Horizontal layout
  70. .PP
  71. .TP
  72. .SH SEE ALSO
  73. .BR jackd(1).
  74. .br
  75. .SH AUTHOR
  76. jkmeter was written by Fons Adriaensen <fons@kokkinizita.net>.
  77. .PP